The SIUI Smartor digital ultrasonic flaw detector and thickness gauge is an upgradable unit that offers one hand operation, flat weld simulation and a smart test wizard. This combination UT and TG detector has up to 14 types of weld simulation, with dynamic beam tracking to visualize the flaw location. Perfect for flat and angle weld testing, thickness measurements on pipes and step blocks, and more. Fully featured unit that is lightweight, has a high IP rating of IP66, and is EN12668-1:2010 (for UT) and EN15317-2007 (for TG) compliant.
Test Wizard
Setup wizard will help users configure the professional operation process, enabling more professional testing.
B-Scan
Display A-Scan echo in imaging mode, to achieve more intuitive test results for easy observation and analysis.
DAC Curve
Easier, more convenient, flaw evaluation
AVG/DGS Curve
Auto created by taking a known flat-bottom hole or large flat-bottom echo for reference.
Weld Simulation
Simulates the weld shape and uses the dynamic beam tracking function to assist the user to quickly determine the location of flaws in the weld.
Probe Spectral Analysis
The probe waveform, spectrum and center frequency of the probe can be measured precisely by capturing echoes.
B-Scan
Based on time interval or encoder, you can display the measurement readings in a B-mode image.
Data Set Management
Measurements are recorded and displayed in grids.
Through-coating Management
After setting the coating velocity, through-coating thickness and coating-thickness can be displayed at the same time.
TDG (Time Distance Gain Curve)
It can be used for compensating the loss of echo amplitude due to propagation of sound path.
TempComp Function
When there is a temperature difference between the calibration block and the detected workpiece, this can be used for temperature compensation.
V-PATH Function
All the original dual element probes have a set of default V-PATH calibration curves. Users can make a set of UserVpath curves for a specific probe.
Display Screen | 5.7" high brightness TFT LCD, 640 x 480 pixels |
Measuring Units | Inch / mm |
Peripheral Ports | USB, SD card (16G) and VGA ports (sharing same mini HDMI with I/O signal port) |
Languages | English, German, Russian, Polish, Hungarian |
Power Supply | DC 12V (external power supply); 7.4V (battery) |
Battery Operating Time | ≥8h (under factory default mode) |
Operating Temperature | 14°F - 113°F (-10°C - 45°C) |
Storage Temperature | -4°F - 140°F (-20°C - 60°C) |
IP Code | IP66 |
Weight | 2 lbs. (0.9kg) including battery |
Dimensions | 8" x 5" x 2" (198 x 128 x 50mm) |
Encoder | 1pc (4-core) |
# of Channels | 1 |
Probe Connector Type | LEMO 00 |
# of Probe Connectors | 2 |
Max Supporting Elements | 2 |
Pulse | Negative Square, Negative spike pulse |
Transmitting Voltage | 50 - 350V, steps 50V |
Pulse Width | Negative Square: 50-500ns, step 10ns Negative spike pulse: ≤40ns |
PRF | Negative Square: 10-1000Hz adjustable, step 10Hz Negative spike pulse: 10-2000Hz adjustable, step 10Hz |
Damping | 50/1000Ω, 2 levels |
A/D Sampling | 240MHz / 10bit |
Sampling Point | 1024 points, 16bit/point |
Gain | 0-110dB, step: 0.5/2/6/12dB |
Fine Gain | -4 - 4 |
Surface Compensation | Full gain range |
Bandwidth | 0.5 - 20MHz (-3dB) |
Operating Frequencies | 1-4MHz / 0.5-10MHz / 1MHz / 2.5MHz / 4MHz / 5MHz / 10MHz / 13MHz / 15MHz / 20MHz, 11 levels |
Rectify | Negative / Positive / Full / RF / Filter |
Reject | 0-80%, step 1% |
Detection Range | 0-39" (0-1500mm), min. display range 0.1" (2.5mm) |
Material Velocity | 100-20000m/s, min step 1m/s |
Pulse Shift Range | -0.4"-40" (-10-1000mm) min step 0.004" (0.1mm) |
Probe Zero | 0-200us, min step 0.01us |
Probe Flank | 0"-4" (0-100mm), step 0.004" (0.1mm) |
Wizard | For weld, plate and forge testing |
Test Point | Peak / Flank / J Frank |
Measurement | Gate: amplitude, amplitude dB difference, sound path, horizontal distance, vertical distance, south path difference between Gate A and B. Cursor: 2 cross cursors, measuring horizontal and vertical positions on B-scan image and distance between cursors (activated optional B-scan) |
Gate Mode | Standard |
# of Gates | 2 |
Gate Start | Full range |
Gate Width | Full range |
Gate Thresh | 10-90%, step 1% |
Calibration | Zero point, zero point + velocity, probe angle |
Alarm | Audible and visual alarm: positive / negative |
Screen Display Combination | Normal, full screen |
Curve Function | Up to 6 DAC (curve / line), up to 10 reference points for each curve line. AVG / DGS |
Axiliary Function | Full screen, coordinates switch (sound path / depth / horizontal), single / continuous auto gain (10-100%, step 10%), SeeColor, WaveComp, WaveFull, PeakEnv, PeakEcho, FastScan, Outdoor, gate magnify, CineRec, PrintScreen. Auto Freeze (Gate: A, B, A and B, A or B) |
Storage Function | Save, recall and delete the parameter, data files, record files, printscreens, depends on the SD card capacity. |
Data Post Processing | Playback, analysis, reports of parameters, record files, printscreen files in SuporUp software. |
Time Base Linearity | ≤0.5% |
Vertical Linearity | ≤3% |
Amplitude Linearity | ≤±2% |
Attenuator Precision | 20dB + 1dB |
Dynamic Range | ≥30dB |
Optional Software | AWS, API, CSC (Curved Surface Correction), TCG, B-Scan, Flat weld simulation, Crack height measurement, Probe Spectrum Analysis. |
# of Channels | 1 |
Probe Connector Type | LEMO 00 |
# of Probe Connectors | 2 |
Max Supporting Elements | 2 |
Work Mode | Standard (R-B1, measurement from transmit pulse to the first bottom wave). All measurements using Zero Crossing. Echo to Echo (B1-B2, measurement by auto-tracking the second bottom wave according to the first wave). Through-coating measurement. |
Pulse | Negative Square, Negative spike pulse (auto fits the probe) |
Transmitting Voltage | 50 - 350V (auto fits the probe) |
Pulse Width | Negative Square: 50-500ns (auto fits the probe) Negative spike pulse: ≤40ns (auto fits the probe) |
PRF | 200Hz |
Damping | 50/1000Ω, 2 levels (auto fits the probe) |
A/D Sampling | 240MHz / 10bit |
Sampling Point | 1024 points, 16bit/point |
Gain | 0-110dB Manually adjustable step: 0.5/2/6/12dB Auto adjustable (auto-search or auto-gain) |
Bandwidth | 0.5 - 20MHz (-3dB) |
Operating Frequencies | 1-4MHz / 0.5-10MHz / 1MHz / 2.5MHz / 4MHz / 5MHz / 10MHz / 13MHz / 15MHz / 20MHz, 11 levels |
Rectify | Negative / Positive / Full / RF |
Reject | 0-80%, step 1% |
Detection Range | 0.02"-24" (0.5-600mm) subject to probe, material, temperature and selected configuration) |
Indication Resolution | 0.0001" / 0.001" / 0.01" (0.001 / 0.01 / 0.1mm) |
Indication Precision Error | 0.03"-0.4" ± 0.002" (0.80-9.99mm ± 0.05mm) 0.4"-4" (10.00-99.99mm ± (1%H + 0.04) 4"-16" (100.00-400.00mm) ± 3%H Tested with TGM5-10L Probe; H is the measured thickness. |
Tube Wall Thickness | With TGM5-10L probe, it can measure steel tubes with diameters no less than 0.8" (20mm) and wall thickness no less than 0.08" (2mm) |
Material Velocity | 100-20000m/s |
Display Range | 0.2"-40" (5-1000mm) |
Pulse Shift Range | -0.4"-20" (-10-500mm) |
Probe Zero | 0-200us |
Gate Mode | Gate A is selected in standard measurement mode |
Gate Start | Gate A start: -0.4"-4" (-10-1000mm), min step 0.004" (0.1mm) |
Gate Width | Gate A width: 0.04"-4" (1-1000mm), min step 0.004" (0.1mm) |
Gate Thresh | Gate A thresh: 10-90% or -10-90% (for RF), step 1% |
Auto Search | Off/on; if enabled, auto adjusts to proper display range, gain and gate position based on the measured wave signals, to improve measurement efficiency. |
Velocity Measurement | Velocity dynamic measurement |
Calibration | Measure the known reference block for fast zero point calibration. Custom calibration (zero point / zero point + velocity calibration) |
Measurement Reading Mode | Std / MinVal / MaxVal / Avg / Diff |
Alarm | Upper and lower limit alarm (sound, indicator light) |
Screen Display Combination | A/BVa, A/Ba/SVa, Ba/BVa (A-Scan + big value / A-Scan + data grid + small value / data grid + big value) |
Refresh Rate of Measurement | 4/8/16/32Hz |
Axiliary Function | Freeze, auto gain, history reading column, last reading maintained, inch / mm switch, outdoor mode. |
Storage Function | Save, recall and delete parameter, data sets, printscreens, depends on the SD card capacity. |
Dataset File | 1D/2D/3D file format Measurements recorded and displayed in grids; record length customizable. Each record point data includes measured values, basic parameter settings and A-Scan waveform data. |
Data Post Processing | Playback, analysis, reports of parameters, data sets, printscreen files in SuporUp software. |
Optional Software | CoatTHK, V-PATH, TDG, Temperature Compensation, Multi-layers measurement, B-Scan. |